ADL400 three phase MID din rail energy meter
● Measurement: 3-phase AC kWh, kVarh, U, I, P, Q, S, PF, F and etc
● Accuracy: 0.5% (kWh)
● Frequency: 45~65Hz
● Rated Voltage: 3x380~456Vac L-L (direct connect); 3x100~120Vac L-L (via PTs)
● Rated Current: 3x80A AC (direct connect); 3x5A or 3x1A AC (via CTs)
● Communication: RS485 (MODBUS-RTU)
● Multi-rate: 4 Tariff Rates and etc
● Data Function: Frozen Data,Max Demand,etc
● Harmonic: 2~31st and total Harmonic
● Standard&Certificate: IEC; CE;CE-MID; EAC

PRODUCTS

  • Features

    1.jpg

    Diverse Electric Parameters Measurement


    ● Harmonic (2~31st voltage¤t)---Standard


    ● F (Frequency)


    ● U (3-phase Voltage)


    ● I (3-phase Current)


    ● kWh (3-phase positive Kilowatt-hours)


    ● kVarh (Kilovar-hours)


    ● P (Power)


    ● Q (Reactive power)


    ● S (Apparent power)


    ● PF (Power factor)

    2.jpg


    Multi-rate/Flexible Tariff


    ● 4 Time zone


    ● 4 Tariff rate (Spike, Peak, Flat, Valley)


    ● 2 Time period list


    ● 14 Time period by day


    ● Data Frozen (last 48 months or last 90 days)


    ● Max demand and occurrence time

    3.jpg


    HMI for Parameters Setting


    ● Code


    ● Protocol


    ● Address


    ● Baud rate


    ● Parity


    ● All Display

    4.jpg


    DIN Rail Installation


    ● 35mm standard DIN rail

    5.jpg


    LCD Display


    ● 12 digits

    6.jpg


    Wiring Instruction

    7.jpg


    Installation Instruction

    8.jpg


    Typical Connection

    9.jpg

  • 1 Function description

     Table 1 Function description list

    Function

    Function description

    Function provide

    Measurement of kWh

    Active kWh (positive and negative)

    Reactive kWh (positive and negative)

    A. B, C split phase positive active energy

    Measurement of electrical parameters

    U、I

    P、Q、S、PF、F

    Measurement of harmonics

    2~31ST Voltage and current harmonic

    LCD Display

    12 bits section LCD display, background light

    Key programming

    3 keys to communication and set parameters

    Pulse output

    Active pulse output

    Multi-tariff and functions

    Adapt 4 time zones, 2 time interval lists, 14 time interval by day and 4 tariff rates

     

    Max demand and occurrence time

    Frozen data on last 48 months, last 90days

    Date, time

    Communication

    Communication interface: RS485, Communication protocol: MODBUS-RTU

     

     

    2.Technical parameter

     

     Table 2 technical parameter descriptions

    Project

    Performance parameter

    Specification

    3 phase 3 wires, 3 phase 4 wires

    Measurement

     

     

    Voltage

    Reference voltage

    3×100V3×380Vac、3×57.7/100Vac、 3×220/380Vac (Can normally work under 1.2 times of rated voltage)

    Consumption

    <10VA(Single phase)

    Impedance

    >2MΩ

    Accuracy class

    Error±0.2%

    Currnt

    Input current

    3×1(6)A, 3×10(80)A

    Consumption

    <1VA Single phase rated current

    Accuracy class

    Error±0.2%

    Power

    Active, reactive, apparent power, error±0.5℅

    Frequency

    45~65Hz,Error±0.2%

     

    Metering

    Energy

    Active energy(Accuracy class: 0.5) reactive energy(Accuracy class 2)

    Clock

    ≤0.5s/d

    Digit signal

    Energy pulse output

    1 active photocoupler output

     

    Pulse

    Width of pulse

    80±20ms

    Pulse constant

    400imp/kWh,10000imp/kWh(Correspond with the basic current)

    Communication

    Interface and communication protocol

     RS485:Modbus RTU

    Range of Communication address

    Modbus RTU:1~ 247;


    Baud rate

    1200bps~19200bps

    Environment

    Working temperature

    -25℃~+55℃

    Relative humidity

    ≤95℅(No condensation)

  • 20200814213804997.png@!w1600

    direct connect

    20200814213805378.png@!w1600

    CT connect