ARD2 Smart Motor Protector Relay
● Suitable for motors with rated voltage of AC380V/660V;
● Optional leakage protection, RS485 communication, analog output, etc.
● 2 channels DI passive dry node input, signal power supply with built-in DC24V power supply;
● 4 channels DO output.

PRODUCTS

  • General

    ARD2 smart Motor Protector is suitable for motors with rated voltage of AC380V/660V, it can protect the motor within rated current range from timeout start-up,overload, blocking, short circuit, under load, unbalance, phase failure and so on.


    Parameters



    1.png


    Accuracy

    Active energy: Class 0.5


    Frequency

    Range: 45-65Hz


    Auxiliary power supply

    AC/DC 85~265V


    Pulse output

    1600-160000imp/kWh


    Consumption

    Voltage: Power consumption <0.5VA;

    Current: Power consumption< 0.5VA;

    Auxiliary power supply:power consumption≤10VA

    Installation: Panel mounted


    Dimension(L*W*H): 96mm*78.5mm*48mm

    2.jpg


    Wiring

    3.jpg


    Typical Connection

    7.jpg


    Application

    8.jpg

  • Parameter

    Technical specification

    Auxiliary power supply

    AC85-265V/DC100-300V, power consumption≤7VA

    Rated voltage

    AC380V/660V, 50Hz/60Hz

    Rated current

    1A(0.1-999.9A)

    Specific current transformer

    5A(0.1-999.9A)

    1.6A(0.4-1.6A)

    6.3A(1.6-6.3A)

    25A(6.3-25A)

    100A(25-100A)

    250A(63-250A)

    800A(250-800A)

    Relay output contactor
    Rated negative capacity

    4 channels, AC250V, 3A

    Switching input

    2 channels,opto-coupler isolation

    Communication

    Standard

    RS485(Modbus-RTU)

    Option(choose one)

    1 or 2 channels Profibus DPV1
    1 channel Profinet
    Ethernet(Modbus TCP)

    Environment

    Operation temperature

    -10℃~+55℃

    Storage temperature

    -20℃~+65℃

    Relative humidity

    ≤95%(No condensation)

    Altitude

    ≤2000m

    Class of pollution

    Level 2

    Protection level

    Main module IP20

    Installation category

    Class III

  • 4.1 Installation dimensions of protector

    Unit: mm

    图片63.png

                                   LED                                                   LCD

                                                       Front view

    图片64.png

    Left view

    图片65.png

    Opening on the surface

    Main body


    Installation dimensions of transformer

    图片66.png

    Current Transformer (0.1A-100A)

    图片67.png

    Current Transformer (63A-250A)

    图片68.png

    Current Transformer (250A-800A)

    图片69.png

    Zero sequence current transformer

    微信截图_20200915203247.png