PZ72L-DE DC Multi-function Power Energy Meter
● Measurement: 1-circuit DC kWh, kVarh, U, I, P and etc
● Accuracy: 0.5%
● Rated Voltage: 1000V DC
● Rated Current: 10A DC (direct connect); 0/4~20mA DC (via Hall Sensor); 75mV (via Shunts)
● Power Supply: 85~265V AC/DC; 20~60V DC
● Communication: RS485 (MODBUS-RTU)
● ±12V Power Ouput: Paired with Hall Sensor
● DI/DO Function: 2/4-channel DI&2-channel DO
● Multi-rate/tariff: 4 Tariff Rates and etc
● Standard&Certificate: CE Certificates

PRODUCTS

  • Products Overview

    Main Functions

    1.jpg

    Panel Overview


    2.jpg

    Main Parameters

    3.jpg


    Dimension

    Outline Dimension

    4.jpg

    Cut-out Dimension

    5.jpg


    Wiring Illustration

    6.jpg

    DC Voltage Signal (1000V DC) Input via direct Connection & DC Current Signal (75mV DC) input via -/75mV Shunts

    7.jpg

    DC Voltage Signal (1000V DC) Input via direct Connection & DC Current Signal (0~20mA or 4~20mA DC) input via Hall Sensors


    Installation Instruction

    8.jpg

    1. Cut out a hole on the object on where we will intall the meter according to dimension of meter referred above.

    2. Remove the buckle on the meter off.

    9.jpg

    3. Install the meter into the cut-out hole.

    4. Buckle up and fixed the meter.


  • 1. Function Overview

    FunctionDescription&Value
    Measurement

    1-circuits DC Voltage, Current, Power, kWh

    Display

    LCD display

    Communication(Optional)

    RS485,Modbus-RTU protocol;(1 start bit,8 data bit,1 stop bit,no parity)

    Baud Rate 1200~38400 bps etc.

    DI/DO Switching(Optional)

    DI (Digital input): 2-channel digital input,dry contact, built-in power supply

    DO (Digital output): 2-channel digital output (relay output) with NO Contact, Capacity:  2A/30V DC or 2A/250V AC

    ±12V Power Output(Optional)

    Serve as the power supply for 1 Hall Sensors with ±12V DC

    Multi-rate/tariff(Optional)

    2 Time Schedules; 4 Time Zone for a year; 12 time periods by days set for 1 time schedule; 4 Tariff Rates (Spike, Peak, Flat, Valley); Min. Time Interval=15 min.


    2. Main Parameters

    ParameterDescription&Value
    InputRated VoltageDC Voltage Input: 0~1000V DC (via direct connetion);  Input Resistance: ≥ 6kΩ/V
    Rated Current DC Current Input: 10A DC (via direct Connection); 0~20mA or 4~20mA (via Hall Sensors); 75mV (via Shunts)
    Overload

    Current&Voltage input overload:1.2 times rated value(continuous); 10 times rated value /1 second

    Power Consumption

    Power consumption of each current input circuit is less than 1mW

    Measuring AccuracyClass0.5%
    Power SupplyVoltage Range 85-265V AC/DC; 20~60V DC (±20%)
    Power Consumption

    ≤ 2W

    Pulse Constant

     

    Voltage and current specifications:750V、300A,Default pulse constant:100imp/kWh

     

    Voltage and current specifications:1000V、300A,Default pulse constant:100imp/kWh

    Insulation resistance

    ≥ 100MΩ

    Power frequency withstand voltage

    Between Power supply//Switching Output// Current Input//voltage Input and Transmitting// Communication //Pulse Output//switching input AC 2 kV 1min;

    Between Power supply、switching output、Current Input、voltage Input AC 2 kV 1min;

    Between Transmitting、Communication、Pulse Output、switching input AC 1kV 1 min;


    3. Environment

    ConditionDescription&Value
    Temperature

    Operation: -25℃+65℃; Storage: -40°C ~+80°C

    Humidity

    ≤95%RH,no condensation,without corrosive gas

    Altitude

    ≤ 2500m



  • Shapepanelshellaperture
    Unit:mmWideHighWideHighDeepWideHigh
    72square75756666986767