● Measurement: 1-phase Active Power, Reactive Power, Current, Voltage and etc
● Current Rating: up to 300A (paired with external CTs)
● Communication: RS485 (MODBUS-RTU)
● Application: Using in distributed Solar PV and Anti-reflux Inverter
● Display: LCD Dispaly
● Dimension: 54*74*85mm (L*W*H)
● Installation: 35mm DIN Rail
● Power Supply: 85~265V AC or 100~350V DC
● Standard&Certificate: CE

PRODUCTS

  • Features

    1.jpg


    Used for distributed Solar PV


    ●Reflux Monitoring 


    ● Harmonic Monitoring

    2.jpg



    Bidirectional Metering


    ● Active Energy Metering


    ● Reactive Energy Metering

    3.jpg


    RS485 Communication


    ● MODBUS-RTU Protocol


    ● Communicate with Inverter to realize anti-reflux Function

    4.jpg


    Single-phase Two-Wire Connection


    ● Paired with external split core CT


    ● Rated Voltage: AC 100V, 400V

    5.jpg


    LCD Display


    ● Parameter Display


    ● Programming Interface

    6.jpg


    Keypads HMI for Programming


    ● Parameter Display Setting


    ● Communication(address, baud rate and etc.)

    7.jpg


    Display Sample

    8.jpg


    Practical Application

    9.jpg

    Solor PV Power Distribution Monitoring Solution

    10.jpg

    ACR10R-DxxT Practical Utility In Distributed Solar PV

  • Technical parameters

    Indicators

    Input

    Grid

    Single-phase

    Frequency

    45~65Hz

    Voltage

    Rated voltage: AC 100V, 400V

    Overload: 1.2 times the rated voltage(continuous); 2 times the rated voltage lasting for 1 second

    Power consumption: less then 0.2VA

    Current

    Rated current: 10A,20A,40A,80A,120A,200A etc. (for details see product specifications)

    Overload: 1.2 times the rated current(continuous);10 times the rated current lasting for 1 second

    Power consumption: less then 0.2VA

     

     

    Output

    Communication

    RS485 interface, Modbus-RTU

    Display

    LCD

    Measurement precision

    Voltage: 0.2 level, current, power Active energy: 0.5 level,0.01Hz frequency, Reactive energy: 1 level

    Power supply

    AC85~265V or DC100~350V; power consumption ≤10VA

     

     

     

    Safety

    Power frequency withstand voltage

    AC2kV 1 min between power supply // current input//voltage input and communication

    AC2kV 1 min between each pair of combinations among power supply, urrent input and voltage input.

    Insulating resistor

    Input,output terminal to housing >100MΩ

    Environment

    Working temperature: -10℃~+55℃;storage temperature: -20℃~+70℃

    Relative humidity:5%~95%,non-condensing; altitude:≤2500m