Din rail temperature and humidity controller
○ Model Number: WHD
○ Brand Name: Acrel
○ Min. Order: 500 Pieces
○ Lead Time: 15 - 20 days
○ Payment Terms: Telegraphic Transfer (TT,T/T)
○ Country of Origin: China (mainland)

PRODUCTS

  • WHD series smart temperature and humidity controller is suitable for adjustment and control of temperature and humidity in equipments of high voltage switchgear, terminal box, ring network panel, box transformer substation etc. It can effectively protect relevant equipment from faults resulting from excessive low or high temperature, creepage or flashover etc.from humidity or condensation.

    1. Number 0f temperature, humidity(or temperature) sensorto beconnected with WHD48,WHD72、WHD20R,WHD46 is up to 1,2, 3 respectively;


    2. Every sensor match with two control output contacts(passive), connected with heater and fan respectively,theheater is used for rising temperature or removing moisture,the fan is used for decreasing temperature;

    3. uxiliary function of WHD46:RS485 communication,alarming output function and transmitting function. Only one can be selected.


    Auxiliary function of WHD48:RS485 communication.

    Auxiliary function of WHD72:Alarming output function,RS485 communication and transmitting function.The latter two can only be selected.

    Auxiliary function of WHD2OR:RS485 communication and alarming output function.Both can be selected at

    the same time.

    ”- C”forcommunication,”-J”foralarming,”-M”fortransmitting.


    4. The connecting wire between sensor and controller must use four-core shielded cable. And its maximum length must not exceed 20 m.

     

     

    Operational principle

    T he controller for temperature and humidity mainly consists of three parts of transmitter, controller, heater(or fan etc.), its operational principle is shown as following:


    The message of temperature and humidity in the box is detected by the sensor and analyzed by the controller: When environmental temperature,

    humidity is up to the presetting value or exceed the presetting value, the controller is giving related signal to contects of relay, then the heater(or fan) is energized and working to heat of dehumidifying; after environmental temperature,humidity is well below the presetting value,the heater(or fan) is deednergized and stop working. In addition to its basic functions, the specific product with different type possess secondary functions such as alarming output for wire-breaking,communication,forced heating etc.